ADM706 Datasheet PDF

Part Series:
ADM706 Series
Category:
-
Description:
3V, Voltage Monitoring Microprocessor Supervisory Circuit
Updated Time: 2023/01/13 02:30:26 (UTC + 8)

ADM706 Datasheet PDF -

17 Pages
ADI
Processor Supervisor 2.63V 2.63V 8Pin PDIP N Tube
17 Pages
ADI
Processor Supervisor 2.93V 2.93V 8Pin SOIC N Tube
17 Pages
ADI
Processor Supervisor 4.4V 4.4V 8Pin SOIC N T/R
16 Pages
ADI
Processor Supervisor 4.4V 250uA 8Pin SOIC N
16 Pages
ADI
Processor Supervisor 2.63V 2.63V 8Pin SOIC N
16 Pages
ADI
Processor Supervisor 4.4V 4.4V 8Pin SOIC N
16 Pages
ADI
Processor Supervisor 2.63V 2.63V 8Pin SOIC N Tube
16 Pages
ADI
Processor Supervisor 3.08V 3.08V 8Pin SOIC N T/R
16 Pages
ADI
Processor Supervisor 2.93V 2.93V 8Pin SOIC N T/R
16 Pages
ADI
Processor Supervisor 2.63V 2.63V 8Pin SOIC N T/R
16 Pages
ADI
Processor Supervisor 2.93V 2.93V 8Pin PDIP N Tube
16 Pages
ADI
Processor Supervisor 2.63V 2.63V 8Pin SOIC N T/R
16 Pages
ADI
Processor Supervisor 2.63V 2.63V 8Pin SOIC N
16 Pages
ADI
Processor Supervisor 4.4V 4.4V 8Pin SOIC N
16 Pages
ADI
Processor Supervisor 2.63V 2.63V 8Pin SOIC N T/R
16 Pages
ADI
3V, Voltage Monitoring Microprocessor Supervisory Circuit

ADM706 - ADI Function Overview

Product Details
The ADM705/ADM706/ADM707/ADM708 microprocessor supervisory circuits are suitable for monitoring 5 V power supplies/batteries and microprocessor activity.
The ADM705/ADM706 provide power-supply monitoring circuitry that generate a reset output during power-up, powerdown, and brownout conditions. The reset output remains operational with VCC as low as 1 V. Independent watchdog monitoring circuitry is also provided. This is activated if the watchdog input has not been toggled within 1.60 sec.
In addition, there is a 1.25 V threshold detector to warn of power failures, to detect low battery conditions, or to monitor an additional power supply. An active low, debounced manual reset input (MR) is also included.
The ADM705 and ADM706 are identical except for the reset threshold monitor levels, which are 4.65 V and 4.40 V, respectively.
The ADM707 and ADM708 provide a similar functionality to the ADM705 and ADM706 and only differ in that a watchdog timer function is not available. Instead, an active high reset output (RESET) is available as well as the active low reset output (RESET). The ADM707 and ADM708 are identical except for the reset threshold monitor levels, which are 4.65 V and 4.40 V, respectively.
All devices are available in narrow 8-lead PDIP and 8-lead SOIC packages.
Applications
Microprocessor systems
Computers
Controllers
Intelligent instruments
Critical microprocessor supply monitoring
### Features and Benefits
Guaranteed RESET valid with VCC = 1 V
190 μA quiescent current
Precision supply voltage monitor
4.40 V (ADM706/ADM708)
200 ms reset pulse width
Debounced TTL/CMOS manual reset input (MR)
Independent watchdog timer (ADM705/ADM706)
1.60 sec timeout (ADM705/ADM706)
Voltage monitor for power fail or low battery warning
Superior upgrade for MAX705 to MAX708
show more