●GPC40 Commercial, 85 to 264 VAC Input, 40 W Global Performance Switchers
● General Specifications
● AC Input:
● 85-264 VAC, 47-63 Hz single phase.
● Hold-Up Time:
● 20 mSec minimum from loss of AC input at full load, nominal line (115 VAC).
● Overload Protect:
● Fully protected against short circuit and output overload.
● Input Protect:
● Internal AC fuse provided on all units.
● Operating Temperature Range:
● 0°–50°C at full rated output power.
● Thermal Shutdown:
● Provided as a standard feature in GPX 130, 140, 200 and 225 models.
● Power Fail:
● TLL of CMOS compatible output goes low (<0.5 V) 5 mSec before output voltage drops more than 4% below nominal voltage upon loss of AC power or 130 W units and above.
● Remote Sense:
● Provided as a standard feature on the +5 V output of GPX 130 and 200 multi-output models and GPX 40, 80, 140 and 225 single-output models.
● Overvoltage:
● Built in on +5 V outputs and all single output models.
● General Specifications (Continued)
● Voltage Adjust:
● Main output adjustable ±5% minimum.
● Overload Protect:
● Factory set to begin power limiting at 115%.
● EMI Compliance:
● All models include built-in EMI filtering to meet or exceed the conducted emissions requirements of FCC 20870 Class B to 30 MHz and CISPR 11/22 Class B.
● Safety:
● All models are approved to CSA22.2 No. 234 Level 3, IEC950, EN60950 and VDE0805.
● Output Noise:
● 1.5% RMS, 1% Pk-Pk, 20 MHz, bandwidth, differential mode.
● Warranty:
● Two years.
●40 Watt convection.
● Overall Dimensions:
● 5.00" × 3.00" × 1.28".
● Weight:
● 0.75 lbs.
● Features:
● Wide Range AC Input 85-264 VAC
● Two-Year Warranty
● Conducted EMI Exceeds FCC Class B and CISPR 22 Class B
● Single and Multiple Outputs
● Approved to UL1950, EN60950 E3:2000 and CSA-C22.2 No. 234
● Marked to LVD