Web Analytics
Part Datasheet Search > - > UC3841 Datasheet PDF
Images are for reference

UC3841 Datasheet PDF

Part Series:
UC3841 Series
Category:
-
Description:
the uc1841 family of pwm controllers has been designed to increase the level of versatility while retaining all of th...
Updated Time: 2023/09/27 09:01:41 (UTC + 8)

UC3841 Datasheet PDF -

11 Pages
TI
Current Mode PWM Controller 1A 500kHz 18Pin PDIP Tube
11 Pages
TI
IC OFFLINE CTRLR PWM PROG 20PLCC
11 Pages
TI
the uc1841 family of pwm controllers has been designed to increase the level of versatility while retaining all of th...

UC3841 - TI Specifications

TYPE
DESCRIPTION
Case/Package
PDIP-18
show more

UC3841 - TI Function Overview

The UC1841 family of PWM controllers has been designed to increase the level of versatility while retaining all of the performance features of the earlier UC1840 devices. While still optimized for highly-efficient boot-strapped primary-side operation in forward or flyback power converters, the UC1841 is equally adept in implementing both low and high voltage input DC to DC converters. Important performance features include a low-current starting circuit, linear feed-forward for constant volt-second operation, and compatibility with either voltage or current mode topologies.
In addition to start-up and normal regulating PWM functions, these devices include built in protection from over-voltage, under-voltage, and over-current fault conditions with the option for either latch-off or automatic restart.
While pin compatible with the UC1840 in all respects except that the polarity of the External Stop has been reversed, the UC1841 offers the following improvements:
1\. Fault latch reset is accomplished with slow start discharge rather than recycling the input voltage to the chip.
2\. The External Stop input can be used for a fault delay to resist shutdown from short duration transients.
3\. The duty-cycle clamping function has been characterized and specified.
The UC1841 is characterized for -55°C to +125°C operation while the UC2841 and UC3841 are designed for -25°C to +85°C and 0°to +70°C, respectively.
All Control, Driving, Monitoring, and Protection Functions Included
Low-current, Off-line Start Circuit
Voltage Feed Forward or Current Mode Control
Guaranteed Duty Cycle Clamp
PWM Latch for Single Pulse per Period
Pulse-by-Pulse Current Limiting Plus Shutdown for Over-Current Fault
No Start-up or Shutdown Transients
Slow Turn-on Both Initially and After Fault Shutdown
Shutdown Upon Over- or Under-Voltage Sensing
Latch Off or Continuous Retry After Fault
PWM Output Switch Usable to 1A Peak Current
1% Reference Accuracy
500kHz Operation
18 Pin DIL Package
show more